We deliver all kinds of columns and towers according to the main international mechanical design codes, using the ultimate design software and under the particular specifications of the client.

Technical Specifications: 

  • Weight, Diameter, Height, Thickness
  • ASME VIII div. 1 – AD-2000-EN 13445 – BS-5500
  • Design Software: Microprotol / Compress / PVElite

General specifications:

  • Weight: Up to 130 tons
  • Diameter: From 200 mm. up to  7.500 mm
  • Height: Up to 50.000 mm
  • Thickness: From 3 mm. up to 50 mm

Features:

  • Supported by means of skirts, brackets or rings
  • Fabrication of internals (trays, supporting rings, distribution pipes…)
  • Heating / Cooling optionally by a double jacket, limped coils or dimple jacket
  • Internal coils available
  • Inserted tube bundles possible
  • Internal polishing, from Ra ≤ 1.2 µm up to Ra ≤ 0.2 µm
  • Internal Electropolishing as an option
  • Supply of ladders, platforms and handrails

Mechanical design:

  • ASME VIII div.1 – AD-2000 – EN-13445 – BS-5500
  • Design software: Microprotol / Compress / PVElite
  • Finite Element Analysis (FEA)
  • Seismic and wind loads calculations according to the pertinent local rules
  • Design of internals: Trays, supports and others
  • Design of platforms, ladders, sliding guides and foundations

Welding:

  • Automatic SAW welding machines
  • Welding machines for GMAW, FCAW and GTAW
  • Certified welding procedures and welders